New Multi-region uptime checks and custom-domain status pages

Scaleway Outage History

Daily provider-status observations and published incident history for Scaleway.

Regional incident

Scaleway has an active regional incident; no global outage is indicated. Verified . Official provider source.

Looking for an update now? Check the current status, or follow Scaleway for future changes.

0% of 56 verified observed days had no reported provider issue

90-Day Trend

Jul 23Oct 20

Dashed calendar markers below identify legacy observations whose source-at-observation was not recorded.

Monthly Status Summary

Month Issue-free days Days Tracked Days with issues
September 2026 0% 30 30

This percentage summarizes normalized provider-status observations by calendar day. It is not duration-based, component-weighted, or contractual uptime. See the methodology and limitations.

Recorded Daily Status (Last 91 Days)

Jul 22 Today
Legacy observation Operational Degraded Partial Outage Major Outage Maintenance No Data

Incident History

September 2026
[NETI] - DC3/S45/C5 - Public switch has rebooted
minor Observed active window 5m

View incident details and source

Started:

DC3 Network
investigating
We are continuing to investigate this issue.
investigating
At 10:10 AM CEST the 11/9/2026, public switch located in DC3 room S45 rack C5 has rebooted. All servers in this racks have lost public connectivity during approximately 10 minutes.
[MGDB] - [fr-par] - Restore Snapshot is broken
minor Observed active window 25h 25m

View incident details and source

Started:

Databases
investigating
The Snapshot Restoration feature is broken. Our team working to fix this situation.
[Jobs][fr-par] some jobs cannot be started due to internal error
minor Observed active window 5h 22m

View incident details and source

Started:

Jobs
monitoring
The situation is back to normal
investigating
100% of jobs cannot be started due to an ongoing issue. We are investigating the cause and will keep you informed as soon as we have more information.
[VPCL] - it-mil-1 - Network Incident on going at IT-MIL-1
major Observed active window 10m

View incident details and source

Started:

Data Warehouse Kafka Kubernetes Kapsule Load Balancer Serverless Container Serverless-Database VPC Website
investigating
We are continuing to investigate this issue.
investigating
Since 11:05 approximately, we lost both BGP sessions towards vpc-route public VMs
[NETI] - DC2/301/D4 - Public switch unavailable
minor Observed active window 38m

View incident details and source

Started:

Network
investigating
We are continuing to investigate this issue.
investigating
Since 08/09/26 at 4:30 AM CEST, public switch located in DC2, room 301, rack D4 is unreachable. All dedibox servers in this rack have lost public connectivity.
[REGX] - [it-mil] - Cannot authenticate/pull/push images
minor Observed active window 1h 31m

View incident details and source

Started:

Container Registry it-mil-1
investigating
We are currently investigating this issue.
[NETI] - DC2 / 202-A / A11 - Switch unreachable
minor Observed active window 4m

View incident details and source

Started:

DC2 Network
investigating
Since 11h48 CEST, public switch located in DC2 room 202-A rack A11 is down. All servers attached to it have lost public connectivity.
[OBJS] - [it-mil] - Elevated error rate - All hive nodes are down
major Observed active window 52m

View incident details and source

Started:

it-mil-1 Object Storage
investigating
Object Storage is now in nominal state, you may have seen errors on PUT and GET.
investigating
We are seeing an elevated error rate on IT-MIL-1 for object storage. Teams are working on it.
[IT-MIL]Multiple APIs are down
critical Observed active window 3h 17m

View incident details and source

Started:

APIs it-mil-1
monitoring
APIs are on a nominal state. Situation is back to normal.
investigating
Teams are still working on the remaining problems.
investigating
Situation is stabilizing on the API side, we are still working to manage side effects.
investigating
APIs for IT-MIL are still unavailable due to remaining network issue.
investigating
The situation is returning to normal. We are currently fixing the side effects. During the incident, management of resources on IT-MIL-1 AZ was not possible through APIs and console.
investigating
We are still working on the incident.
investigating
All APIs hosted on it-mil are down.
[TREM] - Delivery latency
minor Observed active window 18m

View incident details and source

Started:

Transactional Email
investigating
Your domain may suffer from delivery latency. Our team is working to fix this situation.

Legacy Incident Archive

223 archived records restored. These records predate source-at-observation attestation. They are shown as historical ServiceAlert records only and do not establish a provider-reported incident, resolution, duration, or current active state.

June 2026
[WebHosting Elements] - [fr-par] High load on pf-012 platform
minor Source not attested
Last archived state: resolved
View archived record details
investigating
Customers may experience degraded performance on their websites and email services hosted on the pf-012 platform due to high load on an internal component.
[GAPI] - [fr-par2] - mistral-small-3.2 errors rate increasing
minor Source not attested
Last archived state: resolved
View archived record details
monitoring
The situation is back to nominal state, the root cause has been identified and incident responses are back to normal.
identified
Part of our Mistral Small 3.2 infrastructure start becoming un stable with un usual error rates.
[Object Storage] - [fr-par-2] - Thermal shutdown for several storage pods
minor Source not attested
Last archived state: resolved
View archived record details
investigating
Due to abnormal temperature, some storage nodes are being shutdown to prevent data loss. This will impact acces to some objects with one-zone storage class
[RDB] - [fr-par] Managed Database provisioning delays
minor Source not attested
Last archived state: resolved
View archived record details
investigating
Customers may experience delays when provisioning new Managed Database instances or performing operations that require infrastructure changes in the fr-par region due to an issue with an internal dependency.
[Cockpit]-[fr-par] - memory pressure on product-frontend
minor Source not attested
Last archived state: resolved
View archived record details
identified
The issue has been identified and a fix is being implemented.
monitoring
We are continuing to monitor for any further issues.
monitoring
Between 11:50 a.m. and 1:30 p.m., metrics ingestion on FR-PAR was affected due to an operation performed on one of the components to improve its resilience. Metrics and log data are also affected.
[NATS, Queues, Topics & Events] - [fr-par] Monitoring data missing
minor Source not attested
Last archived state: resolved
View archived record details
monitoring
Customers may experience missing monitoring data for NATS, Queues, Topics & Events in the fr-par region.
[Dedibox RPN-SAN] - [DC2/DC3] Storage failures on SAN HA pair HDD-18
major Source not attested
Last archived state: resolved
View archived record details
monitoring
Situation is now stable, we are closely monitoring situation on both members of HA pair.
monitoring
Customers may experience iSCSI connection failures on Dedibox RPN-SAN HA HDD-18 in DC2/DC3. The issue has been identified and is currently being monitored. We apologize for any inconvenience caused and will provide further updates as soon as possible.
investigating
Customers may iSCSI connections failures on Dedibox RPN-SAN HA HDD-18.
[Kafka] - [fr-par] Control plane partial outage
minor Source not attested
Last archived state: resolved
View archived record details
investigating
Customers may experience partial outages when managing Kafka resources due to an issue on the control plane.
[Network infrastructure] - [DC5][PAR-2] Public network issue
critical Source not attested
Last archived state: resolved
View archived record details
monitoring
During routine maintenance, a new configuration was deployed to our backbone routers managing traffic for fr-par-2. An unforeseen configuration conflict resulted in a total loss of public connectivity (blackholing) for all Elastic Metal servers. The configuration was pushed at 08:42 UTC for both IPv4 and IPv6. IPv4 was rollback at 09:20 and IPv6 was rollback at 09:45, restoring all connectivity.
monitoring
The fix has been deployed. Services are up and running. We are monitoring the situation and we will provide more information.
identified
The root cause has been found. A fix is being deployed.
investigating
Customers may experience a partial outage of public network connectivity on Elastic Metal servers in PAR2 (DC5).
[DC5] - Switch unreachable in rack B61
minor Source not attested
Last archived state: resolved
View archived record details
investigating
Customers may experience connectivity issues with servers in rack B61 due to an unreachable switch in the network infrastructure.